Item Link - Use this link for citations and online mentions.
Abstract
Session presented on Saturday, July 25, 2015: Abstract: In the recent years, the importance of reducing alarm fatigue in a clinical environment has taken precedence nationally. Alarm management is one of the Joint Commission's National Patient Safety Goals (2014) because sentinel events have directly been linked to the devices that are generating these alarms. At an acute care facility in Boston, a multi-disciplinary team was formed to conduct a pilot study on the state of telemetry alarms on a surgical floor. The goal of this pilot project was to facilitate an environment of care where nurses are tuned to cardiac telemetry alarms that are clinically significant so more efficient patient care may be provided for truly actionable events. An evidence-based approach was taken utilizing alarms tracking software to capture all telemetry alarms during a twenty-five day time span. Likewise noise meters were placed near telemetry alarm speakers to track decibel levels during the aforementioned timeframe. Analysis of the data showed that clinically insignificant PVC alarms accounted for forty percent of all alarms in the unit within the time span, while also contributing to an average noise level of 57.84 dB in one of the selected areas. In response to the data, the interdisciplinary team approved to permanently default the settings for PAIR PVC, MULTIFORM PVC, and RUN PVC alarms to off. Alarm and noise data were subsequently tracked for an additional 25 days. The results showed a 54% decrease in the rate of alarms per bed per day, and an overall noise reduction of 1.5 dB.
Description
Research Congress 2015 Theme: Question Locally, Engage Regionally, Apply Globally. Held at the Puerto Rico Convention Center.
Repository Posting Date
2016-03-17T12:59:21Z
Notes
Items submitted to a conference/event were evaluated/peer-reviewed at the time of abstract submission to the event. No other peer-review was provided prior to submission to the Henderson Repository.
Type Information
Type | Presentation |
Acquisition | Proxy-submission |
Review Type | Abstract Review Only: Reviewed by Event Host |
Format | Text-based Document |
Category Information
Evidence Level | |
Keywords | Telemetry alarms; Alarm fatigue; Alarm desensitization |
Conference Information
Name | 26th international Nursing Research Congress |
Host | Sigma Theta Tau international, the Honor Society of Nursing |
Location | San Juan, Puerto Rico |
Date | 2015 |
Rights Holder
All rights reserved by the author(s) and/or publisher(s) listed in this item record unless relinquished in whole or part by a rights notation or a Creative Commons License present in this item record.
All permission requests should be directed accordingly and not to the Sigma Repository.
All submitting authors or publishers have affirmed that when using material in their work where they do not own copyright, they have obtained permission of the copyright holder prior to submission and the rights holder has been acknowledged as necessary.
Related items
Showing items related by title, author, creator and subjects.
-
Alarm management: A quality improvement project to decreased non-actionable cardiac telemetry alarms
Paarlberg, Tammy (2016-11-21)A high number of non-actionable cardiac alarms compromise patient safety. Up to 99% of telemetry alarms are false or non-actionable, leaving nurses to guess which 1% of alarms are real. This alarm fatigue phenomenon leaves ... -
Decreasing the Inappropriate Use of Telemetry in a Community Hospital
Matney, Jennifer E.; DeSilva, Eliot (2017-10-20)This presentation will describe a quality improvement project undertaken to decrease alarm fatigue and inappropriate use of telemetry in non-critically ill hospitalized patients by implementing process changes to improve ... -
Reducing Cardiac Telemetry Nuisance Alarms Through Evidence-Based Interventions
Karapas, Eleftheria T.; Bobay, Kathleen L.Cardiac telemetry nuisance alarms are most often due to leads off and poor signal events. Nuisance alarms increase staff workflow interruptions, decrease staff trust in technology, and can compromise patient safety. ... -
Quite alarming! Reducing the incidence of false alarms to prevent alarm fatigue
Zepeda, Mychell G. (2016-03-17)Session presented on Saturday, July 25, 2015: After attending AACN NTI 2013, the NTI Action Pak - Alarm Management was presented to the cardiac performance improvement council. The council reviewed the literature, including ... -
Improving clinical alarm fatigue and alarm management competency among critical care nurses by implementing a unit based alarm management bundle
Bosma, StephanieClinical alarms are designed to signal an unsatisfactory patient physiological state, alert staff to malfunctioning medical equipment or systems, and warn the operator of potential hazards to the patient. While alarms ...