Effectiveness of Central Venous Catheter Needleless Connectors & Protective Caps in Reducing Central Line Associated Blood Stream Infections
View File(s)
Visitor Statistics
Visits vs Downloads
Visitors - World Map
Top Visiting Countries
Country | Visits |
---|
Top Visiting Cities
City | Visits |
---|
Visits (last 6 months)
Downloads (last 6 months)
Popular Works for Nelson, Susan K by View
Title | Page Views |
---|
Popular Works for Nelson, Susan K by Download
Title | Downloads |
---|
View Citations
Citations
The citations below are meant to be used as guidelines. Patrons must make any necessary corrections before using. Pay special attention to personal names, capitalization, and dates. Always consult appropriate citation style resources for the exact formatting and punctuation guidelines.
Item Information
Item Link - Use this link for citations and online mentions.
Abstract
Session presented on Thursday, September 25, 2014: The Effectiveness of Central Venous Catheter Needleless Connectors and Protective Caps in Reducing Central Line Associated Blood Stream Infections. Abstract Background and Significance: There are approximately 250,000 central line-associated blood stream infections (CLABSI) in the U.S. each year. The CLABSI mortality rate in the U.S. is as high as 35%, resulting in 28,000 deaths per year. The development of a CLABSI can increase the hospital length of stay by up to three weeks and has an estimated cost of $16,550.00 (CDC, 2011). The implementation of central venous catheter (CVC) insertion bundles and CVC care and maintenance bundles has been effective in decreasing the incidence of CLABSIs; however, the use of needleless connectors on CVCs has been linked to an increase of CLABSIs. Problem and Purpose: This paper seeks to review the current state of nursing science regarding how these needleless connectors are being cared for, what protocols are being followed for scrubbing the hub, and whether the use of needleless protector caps has an impact on decreasing CLABSIs. Method: A database search was performed to obtain articles written in the English language for review using the following key words: needleless connectors, catheter related blood stream infections, central line-associated blood stream infections, CLABSI, central venous catheter, needleless connector protector cap, needleless cap, infection, disinfection of needleless connectors. Nine of the ten articles chosen for this review focused on care of adult patients with CVCs in an ICU setting using needleless connectors and the incidence of CLABSIs, one article focused on care of children with CVCs. Findings: Four of the ten studies showed that there was no significant difference in CLABSI rates with the use of various types of needleless connectors and/or needleless protector caps even though there was a reduction in CLABSIs during the intervention. Two of the studies revealed that the use of a needleless protector cap may prevent microorganisms entering into the intraluminal pathway and lower the risk of CLABSIs. Three studies involved nurses knowledge of needleless connectors and how to properly disinfect them and indicated that there is a lack of nursing knowledge when it comes to needleless connectors and how they work. One experimental study showed that of the three types of needleless connectors tested, the zero fluid displacement connector performed the best in reducing CLABSIs. All studies agreed that how the needleless connector is maintained plays a major role in the prevention of CLABSIs and that educating clinicians is a key step in preventing CLABSIs. Discussion/Implications: While there was no significant difference in CLABSI rates in these studies, there was a decrease in CLABSI rates with the use of various needleless connectors and needleless connector protective caps. There is a lack of nursing knowledge on how to properly cleanse the needleless connector hub, insufficient evidence on length of time to scrub the hub with a disinfectant, and length of drying time before accessing the needleless connector. Additional research is needed including larger sample sizes, use of various types of needleless connectors, i.e. negative, positive, or zero fluid displacement, and their relationship to CLABSIs. Further clinical effectiveness could strengthen these results by review of needleless connector protective cap use to prevent CLABSIs. Additional studies need to be conducted on disinfectant times required to properly scrub the hub to reduce bacterial transfer.
Description
Leadership Summit 2014 Theme: Personal. Professional. Global. Held at the Indianapolis Marriott Downtown, Indianapolis.
Repository Posting Date
2015-01-15T13:37:11Z
Notes
Items submitted to a conference/event were evaluated/peer-reviewed at the time of abstract submission to the event. No other peer-review was provided prior to submission to the Henderson Repository.
Type Information
Type | Poster |
Acquisition | Proxy-submission |
Review Type | Abstract Review Only: Reviewed by Event Host |
Format | Text-based Document |
Category Information
Evidence Level | |
Keywords | needleless connectors; disinfection of needleless connectors; central line-associated blood stream infections |
Conference Information
Name | Leadership Summit 2014 |
Host | Sigma Theta Tau International, the Honor Society of Nursing |
Location | Indianapolis, Indiana, USA |
Date | 2014 |
Rights Holder
All rights reserved by the author(s) and/or publisher(s) listed in this item record unless relinquished in whole or part by a rights notation or a Creative Commons License present in this item record.
All permission requests should be directed accordingly and not to the Sigma Repository.
All submitting authors or publishers have affirmed that when using material in their work where they do not own copyright, they have obtained permission of the copyright holder prior to submission and the rights holder has been acknowledged as necessary.
Related items
Showing items related by title, author, creator and subjects.
-
Reduced Central Line-Associated Bloodstream Infection by Application of Integrated Evidence-Based Care Bundle in Critically Ill Patients
Shiung, Tao-Fen; Lu, Shu-Fen; Chou, Shin-shang (2012-01-04)(41st Biennial Convention) Central venous catheter-associated bloodstream infections (CBI) are frequent causes of morbidity and mortality in intensive care units (ICU). The purpose of this study is to apply an integrated ... -
Reducing the Occlusion Rate of Percutaneous Central Venous Catheters in Premature Infants in NICU
Lee, Ming Ying; Chang, Chun-ChuOcclusion rate of percutaneous central venous catheters(PCVC) in NICU is 7.2%. The increased occlusion rate factors is lack of assessment checklist -- staff training and recognition of high-risk population. Our solutions ... -
Instituting a Quality Improvement Program at a Community Medical Designed to Reduce Urinary Catheter Days and the Incidence of Catheter Associated Urinary Tract Infections
Davis, Minnie L. (2016-10-07)Background: In the United States (US) it has been reported that approximately 40% of all healthcare-associated infections (HAIs) are indwelling urinary catheter associated. These infections give rise to increased morbidity, ... -
Changing Culture: Central Line Maintenance Practices to Reduce CLABSI in a Medical Oncology Unit
Lynch, Cassandra; Blissenbach, Margaret; Gode, Autumn; Sagorski, Ryan; Joerger, KylaThis educational activity describes a quality improvement project to prevent catheter associated blood stream infection (CLABSI) on a Medical Oncology unit with the implementation of a simulation based education program ... -
Data Analytics for Diagnosis and Prediction of Central Line-Associated Bloodstream Infections in Critical Care Units
Hooshmand, Mary A.; Moghaddass, Ramin; Toledo, Christine; Skordilis, ErotokritosCentral line-associated bloodstream infections (CLABSI) are among leading causes of in-hospital deaths in the US and are a significant factor for increased morbidity, mortality and health care costs. This study examined ...